Schematic view of a central heating, ventilation and air-conditioning system(HVAC) for schools. Credit: Korea Institute of Civil Engineering and Building Technology (KICT)

According to the WHO, about 7 million people die each year due to air pollution. Particulate matter (PM) triggers inflammatory responses in the human body, causing asthma and other respiratory and cardiovascular diseases. It is more fatal for young and growing students. The Korea Institute of Civil Engineering and Building Technology (KICT) has reduced time required to remove particulate matter from the classroom by more than 30% by optimizing the locations of supply and return diffusers for air supplied into the classroom.

Reducing Particulate Matter has been a global task. In 2018, the Korean Ministry of Education (MOE) announced project designed to tighten the fine particles (PM2.5) standards for classrooms to the annual average of 15㎍/㎥. The MOE has strived to remove particulate matter from classrooms, completing its drive to install air purifiers in all elementary schools across the country last year.

As part of these efforts, a research team at KICT led by Dr. Choon-Man Jang developed a central heating, ventilation and air-conditioning system (HVAC) system equipped with HEPA filters for elementary schools in Korea.

This central HVAC requires an air handling unit (AHU) to be installed for each floor of the school to supply clean air to classrooms through ducts. Supply diffusers connected to ducts supply clean air into each classroom, while the indoor air polluted by students’ indoor activities and inflows of particulate matter is discharged through return diffusers and then purified by the AHU.

Airflow cleans up the particulate matter in the classroom
Streamlines inside an elementary school classroom. Credit: Korea Institute of Civil Engineering and Building Technology (KICT)

Dr. Jang’s team applied three-dimensional numerical simulation to design the optimal positioning of supply and return diffusers. In order to demonstrate performance at the same scale as a real-life school facility in Korea, the research team built a “full-scale school environment performance test-bed” and performed experiments.

Tests were conducted to validate the performance of airflow locations—upper supply diffusers and lower window-side return diffusers—which were optimized through numerical simulation. Results show that the time it takes to remove particulate matter (PM2.5) from the validation requirement of 800 m3 per hour has been reduced by more than 30%. This improvement has been achieved by improving the circulation of indoor airflow inside the classroom and consequently reducing air stagnation.

The distributions of streamlines for upper and floor return diffusers show that the airflow discharged from the upper supply diffusers does not reach the floor fully but gets out through the return diffusers on the ceiling. When floor return diffusers are used, however, airflow from the upper supply diffusers reaches the floor where it is evenly distributed. This indicates that optimal airflow control through the optimization of the locations of return diffusers enables the efficient removal of particulate matter. Furthermore, it maintains the even distribution of indoor airflow.

Airflow cleans up the particulate matter in the classroom
Real-time measurement of PM concentration inside the classroom in the test-bed. Credit: Korea Institute of Civil Engineering and Building Technology (KICT)

This composite system can be installed not only in schools but can also be applied for a range of purposes, including other educational facilities and nursing facilities. One of its biggest advantages is that it can remove indoor particulate matter faster than other indoor ventilation systems.

Dr. Choon-Man Jang said, “Indoor particulate matter in schools directly affect students’ health, so it is very important to reduce the time it takes to remove particulates through airflow optimization.”


Poor air quality in classrooms detrimental to wellbeing and learning


More information:
Sungwan Son et al, Air Ventilation Performance of School Classrooms with Respect to the Installation Positions of Return Duct, Sustainability (2021). DOI: 10.3390/su13116188

Provided by
National Research Council of Science & Technology

Citation:
Airflow cleans up the particulate matter in the classroom (2021, August 26)
retrieved 26 August 2021
from https://techxplore.com/news/2021-08-airflow-particulate-classroom.html

This document is subject to copyright. Apart from any fair dealing for the purpose of private study or research, no
part may be reproduced without the written permission. The content is provided for information purposes only.

Stay connected with us on social media platform for instant update click here to join our  Twitter, & Facebook

We are now on Telegram. Click here to join our channel (@TechiUpdate) and stay updated with the latest Technology headlines.

For all the latest Technology News Click Here 

 For the latest news and updates, follow us on Google News

Read original article here

Denial of responsibility! NewsAzi is an automatic aggregator around the global media. All the content are available free on Internet. We have just arranged it in one platform for educational purpose only. In each content, the hyperlink to the primary source is specified. All trademarks belong to their rightful owners, all materials to their authors. If you are the owner of the content and do not want us to publish your materials on our website, please contact us by email – [email protected]. The content will be deleted within 24 hours.